Oridion Capnostream20 Patient Monitor Features

  • No need for manual calibration and zeroing, water traps, or flushing monitor between patients.
  • Shown in a clinical study to reduce clinically insignificant alarms by 53% with the Oridion Smart Capnography SARA algorithm.
  • Connectivity to nurse call, paging, and central monitoring systems.
  • Large, bright color display with an easy-to-use, knob-navigated, flat-menu structure.
  • Dual parameter monitor that supports the current standard of care providing CO2 and SpO2 measurements.
  • 72-hour trends to review patient history.
  • Event marking to compare events and medication administration to changes in patient status.
  • Case recording to help organize patient files.
  • USB output to transfer patient data to USB flash memory devices.
  • Analog output for use in sleep labs and other laboratory environments.
  • RS-232 port for data transfer.
  • If power is lost when the monitor is operating from AC power, it automatically switched to the internal battery pack for power.

Oridion Capnostream20 Patient Monitor Specifications

Power:
Input Voltage: 100 – 240 VAC, 50/60 Hz.
Fuses: Two F3.15A 250 Volt.
Input Power: 90 VA.
Battery:
Battery Type: 14.8 V, 4Ah Lithium-Ion.
Battery Operation: 2.5 hours (without thermal recorder).
Battery Charging Time: 100% in 12 hours.
Screen: 6.4″ color TFT display.
Screen Resolution: 640 x 480 pixels.
Trace Speed: 3.0, 6.3, 12.5, and 25 mm / second.
Waveform Sampling Rate: 75.7 samples / second for SpO2; 20 samples / second for Capnography.
Trend Storage: 8640 point storage.
CO2, EtCO2, FiCO2 Range: 0 – 99 mmHg.
CO2 Waveform Resolution: 0.1 mmHg.
EtCO2, FiCO2 Resolution: 1 mmHg.
CO2 Accuracy:
0 – 38 mmHg: ± 2 mmHg.
39 – 99 mmHg: ± 5% of reading + 0.08% for every 1 mmHg above 38 mmHg.
Respiration Rate Range: 0 – 150 bpm.
Respiration Rate Accuracy:
0 – 70 bpm: ± 1 bpm.
71 – 120 bpm: ± 2 bpm.
121 – 150 bpm: ± 3 bpm.
Flow Rate: 50 ml/minute, flow measured by volume.
Waveform Sampling: 20 samples / second.
Response Time: 2.95 seconds (typical).
Initialization Time: 40 seconds (typical).
Calibration Interval: Initially calibrate after 1,200 operating hours, then once a year or after 4,000 operating hours, whichever comes first.
SpO2 Measurement Range: 1 – 100%.
SpO2 Range:
Adult Mode 0 – 69%: Unspecified.
Adult Mode 70 – 100%: ± 2 digits.
Neonate Mode 0 – 69%: Unspecified.
Neonate Mode 70 – 100%: ± 3 digits.
Pulse Rate Range: 25 – 240 bpm.
Pulse Rate Accuracy:
No Motion Conditions: ± 3 digits.
Motion Conditions: ± 5 digits.
Perfusion Index Range: 0.02 – 20%.